? Strong pulse capability, minimum pulse width can reach 100s
? High test accuracy, range accuracy reaches 6nA ,current is accurate and stable
? Seamless range switching, reject peak switching,high test stability
? Real-time calculation of step SOC , improve the efficiency of rate charge and discharge operation
? Support constant calibration, custom expression variables, BMS variables
? Current and power condition simulation, truly restore diversified usage scenarios
Standard Version | Professional Version | ||
Voltage | Control Range | 0-5V | 0-5V |
Input impedance | 10G Ohm | 10G Ohm | |
Current | Standard Range | ±60A~±2000A,Gradable | ±60A~±2000A,Gradable |
Response Time | ≤5ms | ≤2.5ms | |
Conversion Time | ≤10ms | ≤4ms | |
Resolution | 16bit | 24bit | |
Current & Voltage Accuracy | ≤±0.05% FS | ≤±0.02% FS | |
Power Efficiency | Charge 80%,Discharge 75% | Charge 80%,Discharge 75% |